Reasons and Solutions of Submersible Pump Stop

A small number of users in the process of using the submersible pump will encounter a sudden shutdown of the phenomenon does not work, do not understand the internal structure of the submersible pump will be mistaken for the case of submersible pump quality problems, then the reason for sudden shutdown of the submersible pump What? Here to share your sudden diving pump does not work and the reasons for the sudden shutdown of the submersible pump solution for reference:


    Submersible pump products, such as stainless steel submersible pump products with submersible pump without burning protection device, as long as the submersible pump motor temperature rises above the preset temperature, the submersible pump will automatically start the protection system to stop running the submersible pump, some users to ordinary diving Pump to take delivery of hot water running about 20 minutes after the submersible pump will automatically stop running, submersible pump itself will run during the operation of the heat, if not the use of high-temperature submersible pumps but the general submersible pump will appear suddenly The phenomenon of shutdown If you use a device without the protection of the submersible pump products will lead to the phenomenon of burning the motor. If the sudden shutdown of the submersible pump is due to the high temperature of the medium caused by the submerged pump sudden stop does not work solution is recommended to choose high temperature submersible pump products suitable for high temperature submersible pump temperature up to 80 degrees.

    If the use of submersible pump products is to rely on the configuration of the control cabinet to protect the submersible pumps, such as WQ submersible sewage pump is usually rely on the control cabinet to achieve protection, then the sudden failure of submersible pump does not work may also be due to submersible pump over current Air switch tripping led to a sudden shutdown of the phenomenon of submersible pump, the sudden failure of the submersible pump does not work solution is to improve the use of submersible pump head or a valve installed in the outlet pipe to control the amount of water submersible pump to reduce the submersible pump current Do not over, it will avoid the emergence of such phenomena.

    As the submersible pump does not have any protection measures due to lack of phase or over-temperature, overload caused by submarine pump motor burned suddenly appeared to stop the phenomenon of submersible pumps, repaired after the submersible pump motor should be configured with the corresponding pump control cabinet protection submersible pump.

没有评论:

发表评论